Technical Specifications
Input Voltage
:
100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)
Output Voltage on Mains Mode
:
Same as Input
Output Voltage on UPS Mode
:
200V + 5%V - 10%
Output frequency on UPS Mode
:
50 Hz ± 0.1 Hz
Switching from Mains to UPS
and from UPS to Mains
:
Automatic
Output Waveform on Mains Mode
:
Same as Input
Output Waveform on UPS Mode
:
PURE SINE WAVE
Battery Charging Current
:
Constant Charging Approx 10% of The Rated Battery
Current in AH
Charger
:
Power Factor Controlled Boost Technology
Efficiency
:
2.2KVA: > 80% at 1400W Bulb Load / 36V DC
Inverter Overload / Short Circuit
:
120%≥110% / >250%
Browns Out Mains Voltage
:
100V ± 40V
Technology
:
100V ± 40V
Technology
:
MICRO CONTROLLER / DSP BASED DESIGN
Auto Reset Feature
:
Yes

MAX. LOAD CONDITION set at 230V/50Hz AC Input : 2.2KVA/1400Watt/RL Load, 3KVA/2100Watt/RL Load

NOTE : Because of a policy of continuous product improvement, the specifications are subject to change without notice.